The HT801 (one phone port) and HT802 (two phone ports) connect regular analog phones to Tonet. Each phone port signs in as one person's line.

The default web sign-in is admin / admin. On the V2 models, the password is printed on the sticker on the back of the unit.

Tonet doesn't support fax. Connect phones only.

Which version do you have? The HT801 V2 and HT802 V2 have NET printed by the network port, and their web page calls them HT801V2 and HT802V2. Where the steps differ, this page says V2.

What you need

  • The adapter and its power adapter.
  • A regular (analog) phone and its cord for each port you use.
  • A network cable to your router.
  • A computer on the same network.
  • The SIP details of the person who'll use each phone: User Name, Password and Domain.

Connect the adapter

  1. Plug the phone into the phone port. On the HT802, the first phone goes in port 1 and the second in port 2.
  2. Connect the adapter's network port to your router.
  3. Plug in the power last.

The Power light and the network light come on. The Phone light stays off until the line registers.

Grandstream ATA default IP address

By default, the HT801 and HT802 get their IP address from your router (DHCP), so it depends on your network. To hear it:

  1. Pick up the phone connected to the adapter.
  2. Dial ***. Wait for "Enter the menu option".
  3. Press 02. The adapter reads out its IP address.

HT801, HT802 and V2 default password

ModelUsernamePassword
HT801, HT802adminadmin
HT801 V2, HT802 V2adminPrinted on the sticker on the back of the unit

The first time you sign in, the adapter makes you choose a new password: 8 to 20 characters, with at least one number, one uppercase letter and one lowercase letter. (On the first HT801 and HT802, this starts with firmware 1.0.53.3.)

  1. On the computer, open a browser and type the adapter's IP address, like 192.168.1.50. On a V2, type https:// first, like https://192.168.1.50.
  2. Sign in as admin with the default password.
  3. Set a new password when asked, and write it down.

Lost the new password? Factory reset the adapter. It goes back to its default password.

Enter your Tonet line

  1. Open the port's settings:
    • HT801, HT802: click the FXS PORT tab (on the HT802, FXS PORT1 for the first phone).
    • V2: go to Port Settings, pick the FXS port (on the HT802 V2, FXS PORT1 for the first phone), then General Settings.
  2. Fill in:
FieldEnter
Account ActiveYes (on V2, tick it)
Primary SIP ServerThe whole Domain, including the colon and port, like pbx.example.com:5080
SIP User IDThe User Name from SIP Information
Authenticate IDThe User Name from SIP Information
Authenticate PasswordThe Password from SIP Information
NameThe person's name
NAT TraversalSTUN
  1. Click Apply at the bottom of the page. On V2, click Save and Apply.
  2. Restart the adapter: unplug the power for a few seconds. Many port settings only take effect after a restart.

Turn on STUN

You set NAT Traversal to STUN on the port page above. Now enter the STUN server:

  • HT801, HT802: open the ADVANCED SETTINGS tab. In STUN Server is, enter stun.tonet.ai:3478. Click Apply.
  • V2: go to System Settings › Basic Settings › ATA Settings. In STUN Server, enter stun.tonet.ai:3478. Click Save and Apply.

Check that it registered

  • On the web page, the Status page has a Port Status table. Registration should say Registered for your port. Not Registered means a setting is wrong.
  • The Phone light is on when the line is registered, and off when it isn't.

A dial tone doesn't prove the line works: the adapter can play dial tone even when it isn't registered. Not registered? See Register Failed.

Set up the second phone on an HT802

  1. Plug the second phone into port 2.
  2. Repeat Enter your Tonet line on FXS PORT2, with the SIP details of the person who'll use that phone.
  3. Check the FXS 2 row in Status › Port Status, and the Phone 2 light.

Factory reset the HT801 or HT802

A factory reset erases every setting, including your lines, and brings back the default password.

With the reset button:

  1. Unplug the network cable.
  2. Push a pin into the reset hole and hold it for about 7 seconds.
  3. Take out the pin.

From the phone:

  1. Dial ***, then 99. Wait for the voice to say "reset".
  2. Key in the adapter's MAC address, printed on the bottom of the unit. Numbers stay as they are. For letters, press: A = 22, B = 222, C = 2222, D = 33, E = 333, F = 3333. For example, 000b8200e395 is keyed as 0002228200333395.
  3. The adapter restarts and resets after about 15 seconds.

From the web page:

  • HT801, HT802: on the BASIC SETTINGS tab, set Reset Type to Full Reset and click Reset.
  • V2: under Maintenance, open Restore Factory, set Reset Type to Full Reset and click Reset.

An adapter locked by a previous provider may only restart when you press the reset button. Ask that provider to release it.

Update the firmware

  1. Download the firmware from grandstream.com/support/firmware, under HandyTone ATA's. In October 2026 the latest is 1.0.65.3 for the HT801 and HT802, and 1.0.15.3 for the V2 models.
  2. Upload it:
    • HT801, HT802: on the ADVANCED SETTINGS tab, pick the file (ht801fw.bin or ht802fw.bin) and click Upload Firmware.
    • V2: go to Maintenance › Upgrade, open the Firmware tab, and under Upgrade via Manual Upload, upload the file (ht80xv2fw.bin).
  3. Wait a few minutes. Don't unplug the adapter. Then check the version on the Status page.

Problems?

Next step

Want a desk phone instead of an analog one? See the phones Tonet sells at tonet.ai/desk-phones, or the other setup guides.

On this page